Researchers at the University of Washington created a microfluidic device that measures platelet health in real time. Kiyomi Taguchi/University of Washington
Emergency room doctors often have only a few minutes to determine which patients are in need of a blood transfusion.
But currently doctors have no direct method to assess the health of one of the most critical component of the blood: platelets. These tiny blood cells play a huge role in helping blood clot after an injury.
Now researchers at the University of Washington have created a novel system that can measure platelet function within two minutes and can help doctors determine which trauma patients might need a blood transfusion upon being admitted to a hospital. The team published its results March 13 in Nature Communications.
"Our system requires a tiny amount of blood to look at how healthy platelets are in real time," said co-corresponding author Nathan Sniadecki , an associate professor in the UW Department of Mechanical Engineering. "We found that platelet function is a far better measure of platelet health and whether a trauma patient will need a blood transfusion than current methods."
VIDEO
Platelets are the first responders to any sort of damage to blood vessels.
"They act as a sort of instant patch," Sniadecki said. "They become activated and stick to the damage, and then they rapidly change their shape to stretch and reach out for more of the wound surface or other platelets. Then they begin to come back together to compact and add strength to a clot."
In patients who've experienced trauma, however, platelets can lose the ability to do their jobs, including becoming less able to apply the forces needed to stop bleeding.
"When trauma patients come into the ER, we use a variety of methods to estimate their risk of bleeding, but none of these tests tells us specifically about platelet strength," said co-corresponding author Dr. Nathan White , an associate professor of emergency medicine at the UW School of Medicine.
White, Sniadecki and their team designed a microfluidic device that measures platelet forces in real time. First, the researchers inject a blood sample into the device. As the blood flows through it, the cells hit an obstacle course: tiny blocks and posts jutting up from the base of the device. This activates the platelets. They feel a massive force when they flow over the blocks, and then the surface of both the blocks and the posts are coated with a platelet-activating molecule.
The team designed a microfluidic device that measures platelet forces in real time. As the blood flows through it, the cells hit an obstacle course: tiny blocks and posts jutting up from the base of the device. This activates the platelets. University of Washington
"The block and post structures act like a mini wound surface," said lead author Lucas Ting, who conducted this research as a mechanical engineering doctoral student at the UW. "The platelets attach between the block and post, and they start to snowball. They aggregate to form a miniature plug that then begins to contract and pull the post toward the block. Based on how far the post moves, we can determine how functional the platelets are."
Tiny blocks and posts in the microfluidic device activate platelets and measure their health. This image was taken on a scanning electron microscope, and the block is 15 microns tall, or about one-tenth the thickness of a piece of paper. University of Washington
Sniadecki's lab has used post structures in microfluidic devices before to measure cell forces, but this is the first time that blocks have been added to the mix. Without the blocks, the platelets didn't stick to the posts.
"As the platelets whip around the block, they are forced to change direction rapidly, and that activates the platelets," Ting said.
To test their device, the researchers recruited participants from Harborview Medical Center. After providing informed consent, 93 trauma patients and 10 healthy participants had their blood sampled when they arrived at the center.
The results showed a significant difference between the healthy participants' blood and that of the trauma patients. Trauma patients' platelets had decreased forces compared to healthy participants' platelets. Of the trauma patients, 17 required a blood transfusion during their first 24 hours in the hospital. These patients also had the lowest platelet forces compared to the trauma patients who didn't receive a transfusion.
Sometimes trauma patients have fewer platelets, so one current test in the ER is to count the number of platelets. But when the researchers looked at platelet count for this study, all blood samples "” including those from healthy participants "” had a comparable number of platelets.
"It's a big deal not just knowing how many platelets are in the blood but knowing how well they're actually functioning," White said. "It's not always obvious which patients will need a blood transfusion, and a device like this can really help us make decisions quickly."
Healthy platelets (false colored blue here) attach between the block and post, and then they begin to pull the post toward the block. Healthier platelets pull the post back farther compared to platelets that have experienced trauma. This image was taken on a scanning electron microscope. University of Washington
Currently the team is working to make the device more user-friendly.
"It's still a prototype where you have to have some training in how to operate it to get a reading," said Ting, who is now director of research and development at Stasys Medical Corporation , the company that spun out from this research. "Our goal is to make it user-friendly and comparable to a blood sugar monitoring device where people deposit blood samples on a strip and put it into the reader. Then the reader just takes care of it."
The team also hopes the device will be useful for measuring platelet strength in other areas of medicine, such as measuring how blood-thinning medications like aspirin or Plavix affect different patients or helping neurosurgeons monitor patients for bleeding complications during surgery.
Co-authors include Shirin Feghhi, a senior engineer at BD Biosciences who conducted this research while a UW mechanical engineering doctoral student; Nikita Taparia, a mechanical engineering doctoral student; Annie Smith, who was a mechanical engineering research scientist but is now a research scientist at Stasys; Ari Karchin, the director of operations at Stasys who completed this work as a mechanical engineering postdoctoral fellow; Esther Lim, a scientist at the Seattle Cancer Care Alliance who conducted this research as a research scientist at UW Medicine; Dr. Alex St. John , an assistant professor of emergency medicine at Harborview Medical Center; Xu Wang , a UW emergency medicine research scientist; and Tessa Rue , a biostatistics research scientist. The microfluidics cards used in this study were made at the UW's Nanofabrication Facility .
This research was funded by the Defense Advanced Research Projects Agency Young Faculty Award, the Coulter Foundation Translational Research Award, grants from the Life Science Discovery Fund, the Combined Funding Initiative, University of Washington CoMotion, the National Science Foundation and the National Institutes of Health.
Sarah McQuate, UW News